Relays and Euro lights

McCoy, Charlie CMcCoy at visa.com
Tue Jun 4 08:06:53 EDT 2002


Don't use silicone caulk (see relay cover idea below) as it releases acetic
acid (i.e. vinegar) during the curing process and will cause corrosion on
the contacts.  A 5 minute epoxy with micro-balloons (see your fav hobby
store) is a better weather preventer.

-----Original Message-----
From: Bernie Benz [mailto:b.m.benz at prodigy.net]
Sent: Tuesday, June 04, 2002 9:08 AM
To: Chris Covington
Cc: 200q20V mailing list
Subject: Re: Relays and Euro lights


Simple.  If I were unfortunate enough to live in Chicago, I'd put the relay
package in a plastic bag, just like Audi does with the ECU to protect it
from those that can't keep their drain holes clean.

Bernie

> From: Chris Covington <malth at umich.edu>
> Date: Tue, 4 Jun 2002 09:50:24 -0400 (EDT)
> To: Bernie Benz <b.m.benz at prodigy.net>
> Cc: QSHIPQ at aol.com, 200q20V mailing list <200q20v at audifans.com>
> Subject: Re: Relays and Euro lights
>
> But Bernie, pin configuration aside, you're missing an important factor -
> weather - when you're saying certain in-hood relays work fine for you in
> your dry, (warm?), non-salted-road, Western climate (of course they
> would!) and that they should for Scott as well in his cold, wet,
> road-salted Chicago climate.
> You have more margin for error from Mother Nature, where Scott doesn't.  I
> think weather has more to do with it than the amount of pins in the
> relays.
>
> Chris
> '91 200q20v
>
>
> On Tue, 4 Jun 2002, Bernie Benz wrote:
>
>> Welcome back, Scott.  Good to hear from you.
>>
>> Sounds like you need to use better relays, or move from Chicago.  A 4 pin
>> relay is not the best choice for this high current, two relay
application,
>> IMO.  Bosch and PB make a 5 pin cube relay specifically for this type
app.
>> in which there is a common input to two sets of 30A NO contacts and dual
>> outputs, thus dividing the current between two sets of contacts and
output
>> terminals.  This has great wiring advantages in that only one #12 wire
need
>> go into each socket connector.  In your enviroment maybe the relay cover
>> needs to be replaced with a little silicone caulk.
>>
>> In my 44s I've had my dual relays mounted on the frame member just behind
>> the pass headlight, near where the jump post used to be (it's now
airborne).
>> No heat, no corrosion, no fuses, no problems, and wiring runs are as
short
>> as possible.  In the 89 chassis they are mounted on top of the pass strut
>> tower.
>>
>> Bernie
>>
>>> From: QSHIPQ at aol.com
>>> Date: Tue, 4 Jun 2002 08:34:00 EDT
>>> To: b.m.benz at prodigy.net, brianl at starsys.com
>>> Cc: 200q20v at audifans.com, urq at audifans.com
>>> Subject: Re: Relays and Euro lights
>>>
>>> --
>>> [ Picked text/plain from multipart/alternative ]
>>> Just read this one....  The case of "new" spec vs element exposed
reality.
>>> The problem with relays is they have a life, specifically, they have a
half
>>> life.  The harsher the environment they operate in, the shorter the half
>>> life.  In the case of my "underhood" installed relays in my urq for
>>> instance,
>>> the crap wiring job from alt to relays located them right beside the
>>> radiator
>>> (heat and water/salt).  Which reduced the half life of my relays to less
>>> than
>>> two months.  When these pups get hot and/or wet, there is no guarantee
of
>>> spec.  In fact, in my case '83 urq, the relays would randomly arc
closed,
>>> this is *with* a 30 amp inline fuse (then run the battery down).  This
>>> wouldn't happen if it was sunny, pretty much a guarantee if it was
>>> raining/snowing (after shut down the lights would either stay on, or the
>>> heat
>>> buildup would turn them on in the middle of the night)
>>>
>>> I put up with this for 4 changes of relays in 6 months, until I recently
>>> moved and properly mounted them in the glovebox area, and strung
10/12guage
>>> wire from the battery.  Nary a problem since.  The problem with applying
>>> 200amps relays is a couple fold.  IF your relays are marginal (not new)
you
>>> DO risk the chance of not only arcing them, but welding them closed AND
>>> blowing the bulbs out.  I'm only sharing BTDT.  I assure you Bernie, I
have
>>> and understand  the operating specifications of *new* 12v 4pin relays.
>>>
>>> I'm only sharing what I see in practice, and personal experience.  If
you
>>> routinely replace your relays *before* failure, your
theory/specification
>>> applies.  IME, few routinely replace relays before failure.  In the land
of
>>> winter salt, underhood relays fail quite regularly, so do those high amp
>>> unprotected connections between relay and wiring.  Mounting them near
the
>>> battery post means you put them near the hottest heat generator too
(turbo),
>>> which means half life ain't great.
>>>
>>> "Don't fix if it ain't broke" - ok, but when it does, "Fix it right the
>>> first
>>> time" (?)
>>>
>>> My .02
>>>
>>> Scott Justusson
>>> practical relay install specialist
>>>
>>>
>>> In a message dated 5/31/02 3:20:11 PM Central Daylight Time,
>>> b.m.benz at prodigy.net writes:
>>>
>>>
>>> Do you normally jump start your car with the headlites on?  200 amps
will
>>> flow through a discharged battery with an applied voltage at the jump
>>> terminal of less than, or very little more than the normal system
opperating
>>> voltage, and rapid chargers are voltage regulated, restricting the peak
>>> applied voltage to about 15 volts.  They are designed to be idiot proof!
>>> Further, the arc over voltage of an open relay is well in excess of 600
>>> volts.
>>>
>>> Bernie
>>>
>>>
>>> _______________________________________________
>>> 200q20v mailing list
>>> 200q20v at audifans.com
>>> http://www.audifans.com/mailman/listinfo/200q20v
>>
>> _______________________________________________
>> 200q20v mailing list
>> 200q20v at audifans.com
>> http://www.audifans.com/mailman/listinfo/200q20v
>>
>

_______________________________________________
200q20v mailing list
200q20v at audifans.com
http://www.audifans.com/mailman/listinfo/200q20v



More information about the 200q20v mailing list