Starter lock out?
Bernie Benz
b.benz at charter.net
Sat Oct 25 07:42:23 PDT 2008
Bob,
Did this problem materialize because /when you replaced the ign.
switch? If you had looked at the circuit diagram, Bentley 537, you
would see that the anti theft relay interrupts the starter current.
Could be a problem in that system. TROUBLE SHOOT!
Bernie
On Oct 25, 2008, at 7:05 AM, Rbade12 wrote:
> I get no click from the solenoid upon turning the key. Ignition
> switch is new, starter is known working, battery is newer, solenoid
> wire is good, ground is good.
>
> Audiworld and SJM mention an antitheft relay, #8 and removing it
> and jumping 36 to 38. I have no #8 relay and it is jumpered and it
> appears a factory jump. The cover of the fuse box labels it as
> "starter lock-out AT" , which I'd persume to mean Auto Tranny, so
> I'd wager none of our cars have this relay.
>
> Is there another version of starter lock-out on the 20v? I see no
> mention in Bentley or any other resource available.
>
> Thanks, Bob 91 200q20v
> _______________________________________________
> 200q20v mailing list http://www.audifans.com/mailman/listinfo/200q20v
More information about the 200q20v
mailing list