diagnosis help

Nathaniel Merrill feelstranger at hotmail.com
Wed Feb 8 17:35:10 PST 2012


More tests -
Ground at hall connector shows 0 resistance to ground.
Wires between hall connector and ecu test OK (0.5 Ohm)

Voltage between pins 1 and 3 (ground, and +) is only about 3 V, where it is supposed to be 4.5 - 5.5.
Not sure what to think about that.  Bentley indicates "replace ECU"...
Need a test LED to see if a hall signal is getting though to ECU.

Car is starting regularly, but CEL still lighting.

Drive it to work, and take a chance?  
Hmmm..


> From: feelstranger at hotmail.com
> To: 200q20v at audifans.com
> Subject: RE: diagnosis help
> Date: Wed, 8 Feb 2012 16:34:04 -0500
> 
> 
> Yes, cleared codes before test drive.  Seems like crank sensors are not relevant since it runs fine as long as it starts.
> 
> 
> 
> > Date: Wed, 8 Feb 2012 13:24:14 -0800
> > From: stincalise at yahoo.com
> > Subject: Re: diagnosis help
> > To: 200q20v at audifans.com
> > 
> > Nat, did you clear the fault codes and it came back? I'd have a look at the crank sensors while you're at it. Dizzy timing mark could be off just a tick too.
> > 
> > 
> >  Austin
> > _______________________________________________
> > 200q20v mailing list	 http://www.audifans.com/mailman/listinfo/200q20v
>  		 	   		  
> _______________________________________________
> 200q20v mailing list	 http://www.audifans.com/mailman/listinfo/200q20v
 		 	   		  