[Es2] I checked my fan today it works and it's three
speeds.
Peter Schulz
pcschulz at comcast.net
Tue May 4 17:56:14 EDT 2004
At 05:34 PM 5/4/2004, livinotte at cox.net wrote:
>Figured I send you guys an email.
>
>The motor that I have is working fine. The terminals are a little nasty
>looking but I can clean them up with the dremel.
Josh, make sure that the electrical terminals are still secure- on Paul
Royals car - either the heat, mechanical stress or both, pulled the
terninals away from the internal connections on the fan motor - since the
case was not servicable, we had to buy a new fan.
He replaced his with a six bladed fan
893 119 113 Cooling Fan 104.55
>I tested it with some extra wires that I made and it's definately a three
>speed fan. I think it doesn't run at full blast because the position 6
>relay is only a 40 amp relay.
Make sure the wiring is up to the task, all the way to and from the relay
from my understanding, 1st speed runs with the afterun pump. 2nd comes on
when Auto or Bilevel is selected (AC), 3rd speed is when temp goes over the
major hashmark at about 10 o'clock
-Peter
Peter Schulz
1990 CQ (perpetually awaiting S2 3b engine transplant)
1991 200 20v TQW indigo mica
1991 200 20v TQW titanium grey
Chelmsford, MA USA
peter at audifans.com
More information about the Es2
mailing list