Type 44 fan blower problem

Michael Murphy mjmjr at optonline.net
Tue Oct 10 14:00:51 EDT 2000


"Hale, Duane A WRAMC-Wash DC" wrote:
> 
> Replaced the fan blower motor on the '87 5TQ yesterday, but the fan still
> isn't coming on.  Fuse is okay.  What am I missing? (fan was intermittent
> prior to fan motor r&r).

Assuming this is the Electronic Climate Control...
Pull the power connector off the blower motor, attach a DCv meter to
wire connector, start car, put CC in low or high fan setting, see if you
get +6VDC for low, +12VDC for high at the connector.  If so, you made
big boo-boo (not checking to see if new blower was DOA).  If no voltage
at the blower motor connector, problem lies with either the blower motor
control unit (on top of evaporator housing) or CC head unit.  I can fax
you the 1 page from Bentley that shows the trouble-shooting procedure.
--
Mike Murphy