Eurolight harness questions...

Ti Kan ti at amb.org
Tue Jul 24 11:32:51 EDT 2001


Beatty, Robert writes:
> Going to be redoing my eurolight harness and was wondering... 
> Do i need to have 4 relays... 2 each side for hi/low? or would one high
> relay and one low relay be able to handle the current load?

One relay for the lows and one for the highs is sufficient, if you use
relays that have the appropriate ratings.  I run 90/100W H4s in my 4K
and 40A relays work just great.  Considering that at 12V, a 100W bulb
flows about 8.3A of current (x2 for two lights makes it 16.6A), I think
using a 30A relay would even be good enough.  If you use bulbs of lesser
wattage then it's a no brainer.

-Ti
01 S4 2.7 biturbo quattro
84 5000S 2.1 turbo
80 4000 2.0
-- 
    ///  Ti Kan                Vorsprung durch Technik
   ///   AMB Research Laboratories, Sunnyvale, CA. USA
  ///    ti at amb.org
 //////  http://www.amb.org/ti/
///




More information about the quattro mailing list