output diagnostic
Konstantin Bogach
kbogach at home.com
Thu Jun 7 00:37:28 EDT 2001
It is normal. Each solenoid except cold start valve clicks until you step to
the next test. Cold start valve cycles 10 sec and stops to avoid overflooding.
Konstantin Bogach.
Trevor Irwin wrote:
> When I do the output diagnostic, the carbon canister solenoid and the
> idle stabilizer valve both "click" continouosly *before* I close the full
> throttle switch--indeed, the full throttle switch has no effect on their
> "clicking". On the other hand, the cold start valve only clicks (for a
> total of ten seconds) when the full throttle switch is closed. I know that
> the full throttle switch is good. Is this normal?
> (oh, the car is a '90 100)
>
> -------------------------------
> T. L. Irwin
> T104 Coordinator
> Swain East 335
> 855-3573
> php.indiana.edu/~trirwin
More information about the quattro