AC Problem

Michael Murphy mjmjr at optonline.net
Wed Jun 20 07:31:00 EDT 2001


Vbonz at aol.com wrote:
> 
>    Part 1.1    Type: Plain Text (text/plain)
>            Encoding: 7bit
Razzit frammis aol email, anyway Vince wrote:
> I'm having the following problem with my Air Conditioning.  My blower motor 
> has been taking progressively longer to come on.  When the blower does come 
> on, it works perfectly. <snip>

Simple test for the blower motor (requires a DC voltage meter):
1. Disconnect power connector from blower motor.
2. Fire up the Climate Control.
3. Set fan to high, should get +12V DC at the power connector
4. Set fan to low, should get +6V DC at the connector.

If no to 3 and 4, problem lies elsewhere in CC System (blower control unit).
If yes to 3 and 4, blower motor is "lazy" - one of the first signs that it's
on the way out.  Give a squirt of WD40 to brushes (under cooling hose on 
blower unit) and pray.
hth,
Mike Murphy