Cent. locking system fuse keep burning out

Paul Meyers paul.meyers at citrix.com
Wed Mar 7 15:31:20 EST 2001


the PO on one of my cars had a bad battery leak that ate the plastic on the
vacuum pump housing and thus shorted out the circuit board controller housed
on the bottom of the pump. The acid even ate a hole in the vacuum hose going
forward. If the vac pump's case is intact, check for a green grunge across
the connectors, causing an intermittent short.
Paul Meyers 
Gray 87 5KCSTQ 1.8bar eurolights fuchs 145 kM, replacing electronic ignition
loom 
Pearl 88 5KCSTQ 1.8bar eurolights fuchs bilsteins 127 kM 2pc-em k24 turbo 
Repainted Pearl 87 5KTQA 1.8bar eurolights TT wheels bilsteins 198 kM daily
driver
Blue 86 5KCSTQ parts car 



-----Original Message-----
From: Albert Ng [mailto:alng at expert.cc.purdue.edu]
Sent: Wednesday, March 07, 2001 2:30 AM
To: quattro at audifans.com
Subject: Cent. locking system fuse keep burning out


Hi Guys,


Somehow the fuse for the central locking system on my 5kcst keeps burning
out; it happens more frequently when it's raining and cold.  I am not
sure what's causing it but this has never happened to my 5kcst before. I
was wondering if any lister has experienced the same problem before? What
could be wrong in the system beside the pump?



Thank You



Albert Ng
'87 5kcst



More information about the quattro mailing list