Did you check the 80-amp fuselink for the fan circuit? It's located in a
little black box near the coolant reservoir. It's a flat piece of fusible
material. It can LOOK like it's intact and still be broken. You need to
remove at least one of the screws to be certain it's whole.
At 10:39 PM 08/28/2003 -0400, Tim Leonard wrote:
>This is a multi-part message in MIME format.
>--
>--
>[ Picked text/plain from multipart/alternative ]
>
>
>I am looking for the radiator cooling fan control unit in a 1991 200. It
>is not located in the left kick panel per Bentley. Where is it? Also,
>anyone have insight as to the most likely reasons why the cooling fan will
>not run? It does if power is connected directly to the fan so I know the
>fan is good.
>Thanks,
>Tim Leonard
>ESCARGO
>
>--
>[ tims.jpg of type image/jpeg deleted ]
>--