Fuel Distributor Connectors
Marc Boucher
mboucher70 at hotmail.com
Sun Feb 1 14:41:45 EST 2004
Previously, in testing the fuel distributor and metering system I'd done the following:
Disconnect an injector line from the top of the distributor
Lift the air flow plate
Operate the fuel pump
At this point, since no fuel came out from the fuel distributor it was concluded that this was the failure point.
I'm wondering if the bolts that connect the injector lines aren't perhaps a special design that don't permit fuel to flow unless the lines themselves are connected...Does anyone know if this is the case or if this test seems valid?
Incidentally I've tested and there is fuel flowing both from the pump and back to the pump via the return line when the pump is activated. Has not been pressure tested yet.
Marc
More information about the quattro