re. Fuel Distributor Connectors

Alan Pritchard apritchard at seaeye.com
Mon Feb 2 10:14:20 EST 2004


Iirc they are standard banjo bolts. Therefore fuel should still flow.

Best Regards,

Alan Pritchard,
Network administrator.

Seaeye Marine LTD.
+44 (0)1329 289000
www.Seaeye.com

 -----Original Message-----
From: 	Ben Swann [mailto:benswann at comcast.net] 
Sent:	02 February 2004 15:05
To:	Marc Boucher
Cc:	quattro at audifans.com
Subject:	re. Fuel Distributor Connectors

Marc,

When metering plate is lifted, you should have fuel spewing out the top and
great gushes of fire hazard.  If not, then something is blocking fuel flow
to the injector lines and your trouble is definately in the metering head.
You did a valid test - It may have been safer and saner to pull the
injectors, but this did narrow the problem.

Did you experience resistance when air flow plate lifted, or did it rise
with a slight amount of force?  

Ben

[Previously, in testing the fuel distributor and metering system I'd done
the following:

Disconnect an injector line from the top of the distributor
Lift the air flow plate
Operate the fuel pump

At this point, since no fuel came out from the fuel distributor it was
concluded that this was the failure point.

I'm wondering if the bolts that connect the injector lines aren't perhaps a
special design that don't permit fuel to flow unless the lines themselves
are connected...Does anyone know if this is the case or if this test seems
valid?

Incidentally I've tested and there is fuel flowing both from the pump and
back to the pump via the return line when the pump is activated.  Has not
been pressure tested yet.

Marc]
_______________________________________________
quattro mailing list
quattro at audifans.com
http://www.audifans.com/mailman/listinfo/quattro