Subject: Cooling fan

Ado Sigal a.sigal at bluewin.ch
Mon Jun 28 01:37:44 EDT 2004


Ben Swann wrote:

>Most probably the switch located on the wastegate sheild is short circuited to ground - probably something you did while working on it.  Check for wiring fualt, such as is the wire that is supposed to be connected to the switch somehow touching goround.
>
>Ben
>
>[Date: Sat, 26 Jun 2004 21:21:59 -0500
>From: Jim & Michelle <jimhill at blomand.net>
>Subject: Cooling fan
>To: quattro at audifans.com
>Message-ID: <000701c45bed$a7b43b40$22b590cf at jim-s>
>Content-Type: text/plain; charset="iso-8859-1"
>
>I have another problem.  The blower that blows air across the turbo ( turbo cooler I suppose) stays on all the time even after the engine has cooled, I've never noticed the blower working at all before and now it won't quit, I finally unplugged the connector after about 45 min. with the ignition off.  any suggestions?    88 5kT]
>_______________________________________________
>quattro mailing list
>quattro at audifans.com
>http://www.audifans.com/mailman/listinfo/quattro
>
As Ben said, the ground to the temp. switch is most likely grounded 
elsewhere on the engine, but while you're at it, change the switch for 
one with 83 or 86?C value (not sure which), which works wery well, while 
the other two values of 100 and 120?C, let the underbonnet temp to high.

Ado