> I'm running cis-e in an 87 cgt, meter was hooked up in series with the
> dpr The meter is always reading 1.01mA when the car is running or not,
> warm or cold. if i disconnect the meter the car get's erratic, reconnect
> the plug and it smooths out. if i switch the meter to the uA(micro amp)
> range i can see slight variations+/- 2 uA. It should be in the 10 mA
> range correct?
Correct...
> SHould i be hooking up the meter in parrallel? Could it
> be screwing up the circuit?
The meter should be in series with the circuit. But yours is broken, I
think. Try another one. It also might not be the meter, it might be
whatever harness, wires, or leads you are using to hook it up, too.
But I don't think a 1.01 mA reading whether the engine is *on or off*
tells you anything about the engine. I suspect that all you're doing is
testing the test equipment, and it's failing.
--