Oxygen Sensor for 5KTQ
Robert Myers
Bob at chips-ur-s.com
Tue May 10 21:56:06 EDT 2005
It works much like a pH meter. The meter measures to potential (voltage)
difference between two electrodes. One electrode is in the sample being
tested and the other is in a reference sample (for the pH meter the
reference is a solution of known pH).
At 09:44 PM 5/10/2005, Kneale Brownson wrote:
>*This message was transferred with a trial version of CommuniGate(tm) Pro*
>Why would the sensor need reference air? It doesn't decide anything, just
>"reports" conditions inside the exhaust system. I'd think the "reference
>air" if needed, would be at the ECU. It's the ECU that decides things.
>
>At 09:18 PM 5/10/2005 -0400, Ben Swann wrote:
>
> >
> >I suspect some of the newer designs - 4 to 6 wire sensors actually have a
> >dedicated conduit for reference air.
>
>
>
>-- incoming mail is certified Virus Free.
>Checked by AVG Anti-Virus.
>Version: 7.0.308 / Virus Database: 266 - Release Date: 5/6/2005
Bob
Http://Chips-Ur-S.com
More information about the quattro
mailing list