Coolant fan stays running, help.
Ed Kellock
ekellock at gmail.com
Fri Sep 14 22:07:12 PDT 2007
Check here:
http://www.sjmautotechnik.com/trouble_shooting/cooling.html#fan
Near the end of this section, right before the section about S4/S6
serpentine belt failure, there is a section entitled "RADIATOR FAN RESISTOR
PACK TESTS". Near the end of this section is the following:
"OTHER NOTES: 5000TQ: The 2nd speed fan can also get stuck on due to the
relay contacts getting welded together, there was a service bulletin issued
about this problem. Whenever the ignition key is off the 2nd speed fan
should NOT be running. "
On my Avant, the A/C high pressure switch is bad and the 2nd speed fan runs
constantly but only when the ignition is on.
Ed
> -----Original Message-----
> From: quattro-bounces at audifans.com
> [mailto:quattro-bounces at audifans.com] On Behalf Of Eric Huppert
> Sent: Friday, September 14, 2007 3:25 PM
> To: quattro at audifans.com
> Subject: Coolant fan stays running, help.
>
>
> Having a issue with my sons 90 200TQ where the coolant fan
> runs continuously on 2nd speed. Ignition off, still runs...
>
> So, I started pulling relays to see which one would turn it
> off. Pulled all of the fan relays under the hood, after run
> relay, radiator thermo switch, hi=pressure AC switch. Lo and
> behold, it's still running with ALL of them disconnected?
> Have temporarily disconnected the fusible link on the neg
> side, but need to get this fixed....
>
> Thoughts?
>
> Eric
>
> _______________________________________________
> quattro mailing list
> quattro at audifans.com http://www.audifans.com/mailman/listinfo/quattro
> ---
> Watch this space for ads :)
> No virus found in this incoming message.
> Checked by AVG Free Edition.
> Version: 7.5.487 / Virus Database: 269.13.19/1008 - Release
> Date: 9/14/2007 8:59 AM
>
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.5.487 / Virus Database: 269.13.19/1008 - Release Date: 9/14/2007
8:59 AM
More information about the quattro