[s-cars] Instrument Cluster Guru Wanted - 95 S6
Fred Munro
munrof at sympatico.ca
Sat May 19 14:30:48 EDT 2007
Tom;
With your list of symptoms, I'd suspect a bad ground (cold solder joint or
broken trace). Get a magnifying glass and go over the PCB traces and solder
joints. Touch up anything that looks funky with a soldering iron. This has
worked for me on previous IP problems. ( I never had any problems on my '94
S4 IP. I sold it last Thursday and the Autocheck display fitzed up a couple
days later. Go figure.) I use Stabilant 22A on all the connectors to ensure
good connections.
HTH
Fred Munro
'94 S4 (gone but not forgotten)
'97 S6
-----Original Message-----
From: s-car-list-bounces at audifans.com
[mailto:s-car-list-bounces at audifans.com]On Behalf Of Tom Winter
Sent: May 19, 2007 12:45 PM
To: s-car-list at audifans.com
Subject: [s-cars] Instrument Cluster Guru Wanted - 95 S6
> nah, basic is v=ir & p=vi
>
> v=ir mixes up to give i=v/r & r=v/i
>
> p=vi mixes to v=p/i & i=p/v
>
> mix everything and you end up with p=i^2r
Ok, guys, funny but not that helpful.
I do, after all, want to solve my problem without having to order a new
instrument cluster from the stealer. . .
Anyone done any soldering touch ups for the connections in the I-cluster?
What to look for to determine a bad connection, etc. That's the info I think
I need.
Tom
'95 S6 Avant
_______________________________________________
S-CAR-List mailing list
S-CAR-List at audifans.com
http://www.audifans.com/mailman/listinfo/s-car-list
More information about the S-CAR-List