[Vwdiesel] Engine won't turn off?
    Justin Bennett 
    lug1970 at yahoo.com
       
    Sat Jun 14 20:23:22 PDT 2008
    
    
  
After I turn the ignition switch off the engine still runs.  I checked 
to see if voltage was still on the fuel shutoff solenoid on the IP and 
there is no voltage, so the circuit is working fine.  Can the shutoff 
plunger become magnetized over time and not fall back to stop fuel flow?
Had this happen a couple of times with a 79 rabbit.  The fuel solenoid relay on top of the fuse block wasn't seated all the way.  Had to reposition the defrost duct so that it would quit pushing the relay out of it socket.