[Vwdiesel] Rebuilt IP / Engine Won't Start

William Longyard longyard at ix.netcom.com
Mon Sep 22 03:56:50 PDT 2008


Yes, and I've checked that the outlet bolt's hole isn't plugged.

Bill L.


----- Original Message ----- 
From: <LBaird119 at aol.com>
To: <vwdiesel at vwfans.com>
Sent: Monday, September 22, 2008 3:32 AM
Subject: Re: [Vwdiesel] Rebuilt IP / Engine Won't Start


> In a message dated 9/21/2008 11:57:33 PM Pacific Daylight Time,
> jhsg at sasktel.net writes:
>
>> but that still doesn't explain why it quits
>> when you give it throttle. That sounds like a fuel restriction.  These
>> pumps work off internal case pressure- take away the internal pressure,
>> it all goes to crap- no fuel regulation, no advance...  The banjo with
>> the orfice on the correct line (the return) is critical like Sandy
>> pointed out.
>
>  I hadn't thought to mention that.  It DOES have an "OUT" banjo
> bolt on the return and a regular one on the inlet???  Then the
> OUT one isn't plugged also???
>    Loren
>
>
> **************
> Looking for simple solutions to your real-life
> financial challenges?  Check out WalletPop for the latest news and 
> information, tips
> and calculators.
>      (http://www.walletpop.com/?NCID=emlcntuswall00000001)
> _______________________________________________
> Vwdiesel mailing list
> Vwdiesel at vwfans.com
> http://www.audifans.com/mailman/listinfo/vwdiesel 



More information about the Vwdiesel mailing list