[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: Fan/Pump



At 09:47 AM 6/23/97 CDT, you wrote:

>Put the new switch in for a trip to Dallas - white, no red dot.  Fans 
>run immediately after shutting it down, keep going for about 20-25 
>minutes.  So far, no battery problems.  Figured that for $15 I could 
>afford to use the switch and move it into backup when I got the right 
>one!


For those wondering, I went out and verified the correct thermoswitch part
number for turbo after run cooling... The temp range is 110C-97C, 130C max,
PN 054 919 369B...

********************************AUDI FAN***********************************
                                   EMCM(SW) Dave Head  
87 5KCStq 194K miles                1.7 bar 
    qcusa #3442                 Maitland, Florida   
******************************************************************************