output tests using vag-com
QSHIPQ at aol.com
QSHIPQ at aol.com
Tue May 7 20:42:18 EDT 2002
--
[ Picked text/plain from multipart/alternative ]
To be more specific, the early motronic found in the 91 200 is not supported
by aftermarket 1552 in terms of output test procedures. You should get a
"this function not supported" message, dan. You can get stored fault codes,
but you cannot do output tests with most of these tools.
HTH
Scott Justusson
In a message dated 5/7/02 11:29:08 AM Central Daylight Time,
rbwinchell at yahoo.com writes:
Dan,
You can use VAG-COM with the 2 prong adapter. You
connect to the 2 connectors on the left (not the far
right one).
Block 0 is the only data block supported by the 3B
engine. There are 10 values, which are listed in the
Bentley.
Rob Winchell