[ba] radiator fan issues
Ti Kan
ti at amb.org
Fri Oct 8 05:19:24 EDT 2004
audion at serversmiths.com writes:
> ...
> So, all I can think is that the switch in the bottom of the radiator is
> intermittent in some way.
> But thought I would ask before I go and swop it out as I have to drain
> everything.
Sounds like you either have a bad thermoswitch or intermittent
wiring/contact.
> I noted that there are a couple of different switches available on the
> online parts sources and any advice about those is welcomed.
I think your '82 has just a single-speed fan, right? The different
switches are probably just different specs, designed to activate the fan
at different temperatures. I recommend that you stay with the stock
spec (90-95 deg C cut-in and 85-90 deg C cut-out).
-Ti
--
Ti Kan
http://www.amb.org/ti
Vorsprung durch Technik
More information about the ba-group