radiator fan does not stop
Pat Korach
tm2 at zipcon.net
Mon Sep 10 11:48:16 EDT 2001
Ron
stage 2 relay in 2 position (Engine comp.)
coolant after run control unit in 3 postion ( engine Comp)
Stage 3 relay in 7 postion under dash (lower
left)
Hope this helps
Pat K.
Kirkland,WA
Ron Paletzki wrote:
> Looking for help regarding by radiator fan on an 1989 100. The fan
> will not stop running even when the car is off for over 15 min. I had
> to disconnect the battery to keep it from draining. I though it might
> be the temp sensor or relays so I checked the shop manuals which
> indicated that there are three relays that control the fan, two in the
> main relay box and one in the auxiliary relay box. With the battery
> connected but the key not in the ignition the fan runs even if I
> unplug the temp sensor (bottom left of radiator) and either relay in
> the primary relay penal. So I tried to find the auxiliary relay panel
> behind the lower dash underneath the steering wheel. Well I found the
> relay panel but there was no fan relay in position 7 as the manual
> says. So my question is now what? I would appreciate any help.
> Ron P--
> Ron Paletzki
>
> Research Fellow
> MPS/NINDS
> 36 Convent Dr MSC 4135
> Bldg 36/Rm 4C-23
> Bethesda, MD 20892
> T(301) 435-4643
> F(301) 435-4959
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://www.audifans.com/pipermail/quattro/attachments/20010910/36ce2edd/attachment.htm
More information about the quattro
mailing list