[s-cars]  cold starting problem again
    David Forgie 
    forgied at shaw.ca
       
    Tue Dec 16 07:26:38 PST 2008
    
    
  
Jerry:  From what you describe, power it NOT getting to either the coils OR the POSs.  Since both
the coils and the POSs are powered off the bus-bar No. 15 terminal (under the driver's side knee
 bolster) which is switched power, you have to suspect: a) the ignition switch and/or b) the POSs
(the coils are passive and are controlled by the ECU via the POSs)
Reference Motronic Wiring diagram:  http://forums.audiworld.com/s4s6/msgs/206801.phtml
Info on changing the ignition switch: http://forums.audiworld.com/s4s6/msgs/204624.phtml
Info about the POSs and the fact that brown V6 ones can be used in a pinch:
http://forums.audiworld.com/s4s6/msgs/149771.phtml
Hope this helps.
    
    