[V6-12v] 4444 and still no start
James Whitehouse
jamescarstuff at aol.com
Thu Feb 3 19:43:23 EST 2005
Wiring to/from the ignition output stage, or coils on that side. I don't
have any other ideas for that one I'm afraid - not an area of the car I've
ever had to troubleshoot, thankfully.
James
On 3/2/05 10:36 pm, "Kent McLean" <kentmclean at mindspring.com> wrote:
> The patient: my '94 100 S Avant with 12V V6
>
> I had been getting DTC 4332, which indicates: Ignition Output
> 1, 2, or 3. Possible causes: Short to positive (B+) or ground
> in the ignition output stage and/or wiring connection between
> the ECM and the power output stage, or ECM is faulty.
>
> I replace the aptly-named POS (power output stage) with a used
> part. The car still won't start. I cleared the codes and tried
> again. It's taunting me with 4444 - no codes.
>
> I have yet to test for gas or spark; I'll try that tomorrow.
> In the mean time, any suggestions?
>
> --
> Kent McLean
> '94 100 S Avant
> '89 200 TQ, "Bad Puppy" is no more
> _______________________________________________
> V6-12v mailing list
> V6-12v at audifans.com
> http://www.audifans.com/mailman/listinfo/v6-12v
More information about the V6-12v