> The system is standard CIS K-Jetronic - up to a point. There is no
> vacuum connection to the control pressure regulator (a.k.a. warm-up
> regulator), and no pressure control valve in the metering head
> itself.
....
and later
> With the engine idling at a control pressure of 3.5 bar, I tried
> feeding vacuum into the membrane valve. At 0.7 bar, it reduced
> control pressure by 0.2 bar. This doesn't seem to be very much.
Are you sure that the control pressure regulator is the two spring /
membrane design ?
The vacuum feed experiment might not work on a standard regulator.
............................................