Re: Interesting Solution - 5kcstq warm start problem



In message <199902262234.OAA29557@gonzo.wolfenet.com> Orin Eman writes:

> > > Blood pressure's fine!  38/80  (38 psi residual/80 psi pumped)
>
> > Fine?  No, not really.  'Residual' should really be above 3 bar
> > (44psi).
>
> 80 is a bit low for system pressure too.

I was going to comment on that (I'd prefer to see 86psi) but it's not
relevant to the warm start problem.

> > > "Not vapor lock" I says?  "Fraid knot" says he.
> > > "The old girls got no spark when she's hot"  he goes on.
> > > "My official diagnosis - Hall unit's goin' south" he concludes.
>
> > Hmm.  Coil ground to inlet manifold would have been _my_ first guess.
>
> And the hall sensor would throw a code.  Could be the flywheel sensors
> too.

Yup.  http://www.teleport.com/scottmo has to be a good start.

--
 Phil Payne
 Phone: 0385 302803   Fax: 01536 723021
 (The contents of this post will _NOT_ appear in the UK Newsletter.)