Eurolight harness questions...
Larry C Leung
l.leung at juno.com
Wed Jul 25 21:01:42 EDT 2001
1 30 amp per circuit (high beam then low beam) would be fine.
To check, Watts/Volts = Amps
100W/12V = 8.33 Amps
You need the extra current allowance of hte relays to allow for the surge
needed to start a bulb (there is one), just be certain to use at least 12
ga wire in the loaded (not signal, that could easily be 18 ga) side of
the circuits.
LL - NY
On Tue, 24 Jul 2001 13:17:49 -0400 "Beatty, Robert" <BeattyR at ummhc.org>
writes:
>Going to be redoing my eurolight harness and was wondering...
>
>Do i need to have 4 relays... 2 each side for hi/low? or would one
>high
>relay and one low relay be able to handle the current load?
>
>would make things significantly easier to set up.
>
>Thanks
>
>Rob
>87 5ktq
>