type 44 heater valve
kneale at coslink.net
kneale at coslink.net
Mon Aug 17 06:35:36 PDT 2009
Electrical connection valves are NLA. No problem running the HVAC system
without the electrics, far as I can tell. The valve normally is open under
all circumstances except A/C use, when it closes via the vacuum system that
also opens the recirculation door.
Original Message:
-----------------
From: Nick Lawrence nick at beol.net
Date: Mon, 17 Aug 2009 09:11:59 -0400
To: quattro at audifans.com
Subject: type 44 heater valve
I have '90 100, 90 200, 91 100.
Asking about the water heater valve.
the '91 100 has an electrical connection
the '90 100 has the wirng but has not had a valve with electric since
I've owned it (several years)
the '90 200 no electrical connection on valve, don't remember seeing
any wiring.
So I ask, what is it for? Does it need the connection?
The non_electrical are a little shorter and it is a stretch to fit hoses.
Local flaps don't show a heater valve with an eclectrical connection in
the listings.
TIA
Nick central Ohio
_______________________________________________
quattro mailing list
http://www.audifans.com/mailman/listinfo/quattro
http://www.audifans.com/kb/List_information
--------------------------------------------------------------------
mail2web - Check your email from the web at
http://link.mail2web.com/mail2web
More information about the quattro
mailing list